{"id":147,"date":"2015-10-09T17:51:30","date_gmt":"2015-10-09T17:51:30","guid":{"rendered":"http:\/\/broker.commercegurus.com\/?page_id=147"},"modified":"2018-11-14T08:55:01","modified_gmt":"2018-11-14T08:55:01","slug":"agricultural-processing","status":"publish","type":"page","link":"https:\/\/www.thofudiagnostics.com\/?page_id=147","title":{"rendered":"M2000 REALTIME SYSTEM"},"content":{"rendered":"
[vc_row type=”container” padding_top=”” padding_bottom=”” css=”.vc_custom_1449576470084{margin-bottom: 0px !important;}”][vc_column width=”1\/2″][vc_column_text]CE Marked<\/strong><\/p>\n The Abbott\u00a0m<\/em>2000 RealTim<\/em>e System is a highly flexible and proven solution featuring a broad menu of IVD assays:<\/p>\n The\u00a0m<\/em>2000 System gives today’s labs the consistency and the confidence they need \u2013 all on a single platform.[\/vc_column_text][\/vc_column][vc_column width=”1\/2″][vc_single_image image=”70917″ img_size=”full” add_caption=”yes” onclick=”link_image”][\/vc_column][\/vc_row][vc_row type=”container” padding_top=”” padding_bottom=”” css=”.vc_custom_1444503683289{margin-bottom: 0px !important;}”][vc_column][vc_separator color=”#e2e2e2″ type=”normal” thickness=”1″ up=”” down=”” el_class=”dotted”][\/vc_column][\/vc_row][vc_row type=”container” padding_top=”” padding_bottom=”” css=”.vc_custom_1542185693758{margin-bottom: 50px !important;background-color: #1e73be !important;}”][vc_column][vc_tta_tabs style=”flat” active_section=”1″][vc_tta_section title=”DESCRIPTION” tab_id=”1444300654474-2bfb86dc-fd3a”][vc_column_text]Real Advantages for Your Lab<\/strong><\/p>\n The\u00a0m<\/em>2000 RealTim<\/em>e System incorporates a unique combination of leading science and enabling solutions.<\/p>\n Leading Science<\/b><\/p>\n Enabling Solutions<\/b><\/p>\n [\/vc_column_text][\/vc_tta_section][vc_tta_section title=”DESIGN” tab_id=”1444300654691-e081e086-5ad3″][vc_column_text]<\/p>\n With smart system design, the\u00a0m<\/em>2000sp<\/em>\u00a0fully automates the extraction of nucleic acid from the specimen and performance PCR plate preparation.<\/p>\n Positive ID Barcode Reader<\/b><\/p>\n<\/div>\n Flexible Sample Processing<\/strong><\/p>\n Load-And-Go Capability<\/strong><\/p>\n Output Deck<\/strong><\/p>\n One Platform, Multiple Uses<\/strong><\/p>\n Custom Software<\/strong><\/p>\n Smart System Design<\/strong><\/p>\n Abbott offers multiple sample preparation systems that will meet your needs as your lab’s testing volume increases:<\/p>\n <\/p>\n 1.\u00a0m<\/em>2000sp<\/em>\u00a0(medium throughput)<\/strong><\/p>\n Fully automated sample preparation system, including master mix creation and 96-well PCR tray generation<\/p>\n <\/p>\n <\/p>\n <\/p>\n <\/p>\n 2.\u00a0m<\/em>24sp<\/em>\u00a0(low to mid throughput)<\/strong><\/p>\n Automated sample preparation system completely automates sample purification steps<\/p>\n <\/p>\n <\/p>\n <\/p>\n <\/p>\n 3. Abbott Manual Sample Preparation\u00a0<\/strong><\/p>\n Useful for laboratories with small volume requirements. Offers reliable extraction using\u00a0m<\/em>Sample preparation chemistry and is interchangeable with other extraction systems in the\u00a0m<\/em>System family.<\/p>\n <\/p>\n <\/p>\n <\/p>\n The\u00a0m<\/em>2000rt<\/em>\u00a0fully automates the amplification and detection of DNA, RNA, or TNA.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=”MENU” tab_id=”1444412836340-fe4dda89-2f8e”][vc_column_text]<\/p>\n [\/vc_column_text][\/vc_tta_section][vc_tta_section title=”SPECIFICATIONS” tab_id=”1542185208396-54eca42e-c2ad”][vc_column_text]<\/p>\n [\/vc_column_text][\/vc_tta_section][vc_tta_section title=”MORE” tab_id=”1542185263020-16568c9b-41fe”][vc_column_text]The\u00a0m<\/em>2000 offers more capabilities to streamline your lab operations:<\/p>\n m<\/em>axCycle<\/strong><\/p>\n m<\/em>axCycle is a reliable solution that allows for simultaneous processing of assays to help labs maximize sample throughput and reduce TAT for faster results reporting to physicians and patients.\u00a0m<\/em>axCycle allows the following assays to simultaneously be processed:<\/p>\n m<\/em>Plus<\/strong><\/p>\n <\/p>\n [\/vc_column_text][\/vc_tta_section][\/vc_tta_tabs][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":" [vc_row type=”container” padding_top=”” padding_bottom=”” css=”.vc_custom_1449576470084{margin-bottom: 0px !important;}”][vc_column width=”1\/2″][vc_column_text]CE Marked The Abbott\u00a0m2000 RealTime System is a highly flexible and proven solution featuring a broad menu of IVD assays: Allowing consolidation of PCR testing on a single, reliable, high performance platform Availability of Laboratory Defined Applications (LDA) The\u00a0m2000 System gives today’s labs the consistency and the confidence […]<\/p>\n","protected":false},"author":1,"featured_media":70778,"parent":73,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/www.thofudiagnostics.com\/index.php?rest_route=\/wp\/v2\/pages\/147"}],"collection":[{"href":"https:\/\/www.thofudiagnostics.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.thofudiagnostics.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.thofudiagnostics.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thofudiagnostics.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=147"}],"version-history":[{"count":4,"href":"https:\/\/www.thofudiagnostics.com\/index.php?rest_route=\/wp\/v2\/pages\/147\/revisions"}],"predecessor-version":[{"id":70921,"href":"https:\/\/www.thofudiagnostics.com\/index.php?rest_route=\/wp\/v2\/pages\/147\/revisions\/70921"}],"up":[{"embeddable":true,"href":"https:\/\/www.thofudiagnostics.com\/index.php?rest_route=\/wp\/v2\/pages\/73"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thofudiagnostics.com\/index.php?rest_route=\/"}],"wp:attachment":[{"href":"https:\/\/www.thofudiagnostics.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=147"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}\n
\n
\n
\n
\n
\n
\n
\n
\n
\n\n
\n m<\/em><\/span>2000 SYSTEM TEST MENU<\/td>\n<\/tr>\n \n RealTim<\/em>e HIV-1 Qualitative<\/td>\n<\/tr>\n \n RealTim<\/em>e HIV-1 Quantitative<\/td>\n<\/tr>\n \n RealTim<\/em>e HBV<\/td>\n<\/tr>\n \n HBV Sequencing<\/td>\n<\/tr>\n \n RealTim<\/em>e HCV<\/td>\n<\/tr>\n \n RealTim<\/em>e HCV Genotyping II<\/td>\n<\/tr>\n \n RealTim<\/em>e High Risk HPV<\/td>\n<\/tr>\n \n RealTim<\/em>e CT\/NG<\/td>\n<\/tr>\n \n RealTim<\/em>e CT<\/td>\n<\/tr>\n \n RealTim<\/em>e CMV<\/td>\n<\/tr>\n \n RealTim<\/em>e EBV<\/td>\n<\/tr>\n \n RealTim<\/em>e MTB<\/td>\n<\/tr>\n \n RealTim<\/em>e MTB RIF\/INH Resistance<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n \n\n
\n m<\/em>2000sp\u00a0<\/em><\/span>SPECIFICATIONS<\/td>\n<\/tr>\n \n Total Width<\/td>\n 145 cm (57.1 in)<\/td>\n<\/tr>\n \n Total Height<\/td>\n 177.5 cm (69.9 in) instrument and cabinet<\/td>\n<\/tr>\n \n Total Depth<\/td>\n 79.4 cm (31.3 in)<\/td>\n<\/tr>\n \n Weight<\/td>\n 297.4 kg (655.7 lbs) instrument and cabinet<\/td>\n<\/tr>\n \n Power Source<\/td>\n 100-240 V<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n \n\n
\n m<\/em>2000rt\u00a0<\/em><\/span>SPECIFICATIONS<\/td>\n<\/tr>\n \n \u00a0Total Width<\/td>\n \u00a034 cm (13.4 in)<\/td>\n<\/tr>\n \n \u00a0Total Height<\/td>\n \u00a049 cm (19.3 in)<\/td>\n<\/tr>\n \n \u00a0Total Depth<\/td>\n \u00a045 cm (17.8 in)<\/td>\n<\/tr>\n \n \u00a0Weight<\/td>\n \u00a034.1 kg (75.2 lbs)<\/td>\n<\/tr>\n \n \u00a0Power Source<\/td>\n \u00a0100-240 V<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n \n